ENVIRONMENTAL |
• |
Operating Temperature: 0 to 70°C
/ 32 to 158°F |
• |
Derate Linearly from
100%
Load at 50°C to 50% Load at
70°C
100% Load at 122°F to 50% Load
at 158°F |
• |
Storage Temp: -40
to 85°C / -40 to 185°F |
• |
Operating Humidity : 0
- 95% |
• |
Storage Humidity:
0 - 95% |
• |
MTBF: 100,000 Calculated
Hours |
|
|
MODEL SPECIFICATIONS
Model No. |
Output Voltage |
Max. Output Current |
Total Regulation |
Max. Output Power |
Certificate |
MBU120-102 |
5 - 6VDC |
20.00 - 16.66A |
7% |
100W |
UL, CB, CE, FCC, T-mark,
RoHS |
MBU120-103 |
6 - 9VDC |
18.33 - 12.22A |
7% |
110W |
UL, CB, CE, FCC, T-mark,
RoHS |
MBU120-104 |
9 - 11VDC |
13.33 - 10.90A |
5% |
120W |
UL, CB, CE, FCC, T-mark,
RoHS |
MBU120-105 |
11 - 13VDC |
10.90 - 9.23A |
5% |
120W |
UL, CB, CE, FCC, T-mark,
RoHS |
MBU120-106 |
13 - 16VDC |
9.23 - 7.50A |
5% |
120W |
UL, CB, CE, FCC, T-mark,
RoHS |
MBU120-107 |
16 - 21VDC |
7.50 - 5.71A |
3% |
120W |
UL, CB, CE, FCC, T-mark,
RoHS |
MBU120-108 |
21 - 27VDC |
5.71 - 4.44A |
3% |
120W |
UL, CB, CE, FCC, T-mark,
RoHS |
MBU120-109 |
27 - 33VDC |
4.44 - 3.63A |
2% |
120W |
UL, CB, CE, FCC, T-mark,
RoHS |
MBU120-110 |
33 - 40VDC |
3.63 - 3.00A |
2% |
120W |
UL, CB, CE, FCC, T-mark,
RoHS |
|
|